Overview detectors / measuring principles
|
Detectors for Ammonia (NH3) |
|
Measuring principle |
Standard range |
Types |
Output |
|
Semi conductive |
0-4000 ppm |
Gx230-(NH3), Gx24-(NH3) |
Three relays |
|
|
|
GJ-EX-NH3-4000 |
Depending on monitoring unit |
|
|
|
MP-series |
Depending on monitoring unit |
|
Chemosorption |
|
CS-21-(NH3) |
4-20mA |
|
Charge carrier inject. |
30-200 ppm |
CI21-200 |
4-20mA |
|
|
30-1000 ppm |
CI21-1000 |
4-20mA |
|
|
30-10000 ppm |
CI21-10000 |
4-20mA |
|
Catalytic |
300-20000 ppm |
CEX300-(NH3) |
Depending on monitoring unit |
|
|
0-40000 ppm (4%) |
CC28-NH3 |
4-20mA |
|
Electrochemical |
0-1000 ppm |
OLCT40-(NH3) |
4-20mA |
|
|
0-1000 ppm |
EC28-NH3-1000 |
4-20mA |
|
IR absorption (NDIR) |
0-25000 ppm |
IR-em 8 / IR-em 16 |
One (1) DO / channel. Two alarm relays and fault relay |
|
Detectors for refrigerant as HFC (HCFC, CFC) and mixtures |
|
The HFC detector is also used for HCFC and CFC gas. |
|
Measuring principle |
Standard range |
Types |
Output |
|
Semi conductive |
0-4000 ppm |
Gx230-HFC, Gx24-HFC |
Three relays |
|
|
|
MP-series |
Depending on monitoring unit |
|
Chemosorption |
|
CS21-HFC |
4-20mA |
|
IR absorption (NDIR) |
0-25000 ppm |
IR-em 8 / IR-em 16 |
One (1) DO / channel. Two alarm relays and fault relay |
|
|
|
|
|
|
Detectors for flammable Hydrocarbon gases (CH) as propane (LPG), methane etc |
|
Measuring principle |
Standard range |
Types |
Output |
|
Semi conductive / |
0-40% LEL |
GS230-(CH), GS24-(CH) |
Three relays |
|
|
|
GJ-EX-(CH) |
Depending on monitoring unit |
|
|
|
MP-DS-(CH) |
Depending on monitoring unit |
|
Chemosorption |
0-50% LEL |
CS21-Methane-50 |
4-20mA |
|
Catalytic |
0-100% LEL |
CEX300 |
Depending on monitoring unit |
|
|
0-100% LEL |
TR5200-DC |
4-20mA |
|
|
|
|
|
|
Detectors for carbon dioxide (CO2) |
|
Measuring principle |
Standard range |
Types |
Output |
|
IR absorption (NDIR) |
0-5000, (0-30000) ppm |
aSense (Room mounting IP21, IP54) |
4-20mA / (0-10V), relay |
|
|
|
UG-aSense (Duct mounting) |
4-20mA / (0-10V), relay |
|
|
|
LT-aSense (Freezing rooms IP54) |
4-20mA / (0-10V), relay |
|
Detectors for Oxygen (O2) |
|
Measuring principle |
Standard range |
Types |
Output |
|
Electrochemical |
0-30% |
GMA36 Pro |
Three relays |
|
|
0-25% |
EC 28 EX |
4-20mA |
|
|
0-30% |
CTX300 |
Depending on monitoring unit |
|
|
|
|
|
|
Detectors for Carbon monoxide (CO) |
|
Measuring principle |
Standard range |
Types |
Output |
|
Semi-conductive |
(0-200 ppm) |
Gx230-(CO), Gx24-(CO) |
Three relays |
|
|
|
MP-series |
Depending on monitoring unit |
|
|
|
|
|
|
Electrochemical |
0-200 (300) ppm |
TR2000 |
4-20mA (2-10V) |
|
|
|
|
|
|
|
|
|
|
|
Detector for Nitrogen dioxide (NO2) |
|
Measuring principle |
Standard range |
Types |
Output |
|
Electrochemical |
0-10 ppm |
TR3210-NO2 |
4-20mA (2-10V) |